    LDC11Y Pipeline Electromagnetic Flowmeter High Accuracy

    LDC11Y Pipeline Electromagnetic Flowmeter is a velocity flow meter, which is the product of the combination of fluid mechanics and electromagnetics. It consists of two parts: a flow sensor and a converter. The upper and lower parts of the measuring tube are equipped with an excitation coil, and the magnetic field generated after passing through the excitation current passes through the measuring tube, and a pair of signal electrodes are installed on the inner wall of the measuring tube to contact with the liquid, generating an induced electric potential, and the flow signal is transmitted to the converter, which is converted into a standard signal for output after the converter. It has the advantages of high precision, high stability, anti-interference, and maintenance-free.


    Basic parameters
    Measuring mediumLiquid (the conductivity of the measured fluid should be > 20μS/cm and compatible with the contact material)
    Flow rate range0.1m/s-15m/s
    Measuring range0.05~21700m3/h
    Range ratio10:1 (15:1, 20:1, 30:1 can be customized)
    Flow directionPositive, negative, net flow
    Repeatability error1/3 of the absolute value of accuracy level
    Accuracy level0.5 level, 0.2 level
    Medium temperature-20℃~60℃ (Chloroprene CR lining)
    -20℃~60℃ (Polyurethane rubber PU lining)
    -30℃~120℃ (PTFE lining)
    -30℃~150℃ (High temperature PTFE lining)
    -30℃~100℃ (Fluorinated ethylene propylene F46 lining)
    -20℃~150℃ (PTFE and perfluoroalkyl vinyl copolymer PFA lining)
    Output signal4~20mA, frequency/pulse, alarm output, RS485, HART
    Power supply85~250VAC,20~36VDC
    Explosion-proof typeEx db ib q IIC T6 Gb (compound explosion-proof including isolation type, intrinsic safety type, sand filling type)
    ConnectionFlange connection DN6-DN2000 (implementation standard GB/T9124.1-2019)
    Protection levelIntegrated IP66
    Split sensor IP66/IP68 Display box IP66
    Note 1/When the split sensor is IP68, the burial depth is less than 5m and the water penetration depth is less than 3m.
    Note 2/The above protection level refers to the level achieved after the electrical connection is complete.
    Maximum Power≤20W
    Show HeaderLCD (with backlight)
    Instrument function
    monitorVolume flow, mass flow, instantaneous flow, cumulative flow, flow velocity
    Call the policeEmpty pipe identification alarm, electrode contamination alarm, excitation alarm
    Current output
    Maximum load750Ω(24V power supply)
    Response frequency1Hz
    Frequency Output
    Frequency output range1~5000Hz
    Output electrical isolationOptical isolation, isolation voltage>1000VDC
    Frequency output driverField effect tube output, maximum withstand voltage 36VDC, maximum load current 250mA
    Pulse output
    Pulse equivalent0.001~1.000 m3/cp
    n0.001~1.000 Ltr/cp
    n0.001~1.000 T/cp
    High level amplitude>22VDC
    Low level amplitude<0.8VDC
    Pulse Width50ms (square wave), automatic average square wave at high frequency
    Electrical isolationOptical isolation, isolation voltage>1000VDC
    Pulse driveField effect tube output, maximum withstand voltage 36VDC, maximum load current 250mA
    Alarm output
    Alarm output contactALMH-Upper limit alarm
    ALML-Lower limit alarm
    Output electrical isolationOptical isolation, isolation voltage>1000VDC
    Alarm output driverDarlington output, maximum withstand voltage 36VDC, maximum load current 250mA
    RS485 outputThis protocol complies with the Modbus communication protocol and adopts the RTU mode in the Modbus protocol. RS485 half-duplex working mode
    (see the protocol description for details).
    Environmental conditions
    Ambient temperature-20~60℃
    Ambient humidity0%~95%RH (no condensation and no condensation)
    Electrical protection
    Insulation resistance≥100MΩ 500VDC
    Dielectric strength500VAC
    Overall material
    Lining materialNeoprene CR, polyurethane rubber PU, polytetrafluoroethylene PTFE,
    high temperature polytetrafluoroethylene PTFE, polyperfluoroethylene propylene F46,
    copolymer of polytetrafluoroethylene and perfluoroalkyl vinyl PFA (contacting the measured medium)
    Electrode materialTitanium, Hastelloy C, Tantalum, Tungsten Carbide, Platinum, 316L (in contact with the measured medium)
    Sensor housingCarbon steel/304 stainless steel
    Flange materialCarbon steel/304 stainless steel
    Converter housingDie-cast aluminum
    Converter sealsNitrile rubber
    Display window≈6mm explosion-proof glass
    Connect the cablesCable between sensor and converter 2*0.5 OD 6.5mm PVC shielded cable (split type)
    manual
    Product Information—Chinese (CN)PDF
    Product Information—English (EN)PDF
    Product Selection—Chinese (CN)PDF
    Product Selection—English (EN)PDF
    Installation Instructions—Chinese (CN)PDF
    Installation Instructions—English (EN)PDF
    RS485 (RTU) Protocol Description—Chinese (CN)PDF
    RS485 (RTU) Protocol Description—English (EN)PDF
    HART Protocol Description—Chinese (CN)PDF
    HART Protocol Description—English (EN)PDF
    Key Operation Instructions—Chinese (CN)PDF
    Key Operation Instructions—English (EN)PDF

    Quality LDC11Y Pipeline Electromagnetic Flowmeter High Accuracy for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Star Sensor Manufacturing Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)